Soc. The paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. . by GDS Team | May 27, 2015 | Electrochemical Sensors. Less expensive than most other gas detection technologies, such as infrared and PID technologies. Developing a sensor with a low LOD is crucial because often analytes exist at trace concentrations in real samples. We present a fundamental description of the three major electrochemical sensing methods used in the detection of pathogens and the advantages and disadvantages of each of these methods. Sensor accuracy decreases until it becomes unreliable and no longer suitable to fulfill its task. An example of such a design challenge is an instrument with a multigas configuration, which measures several target gases. Causes of GPS errors Why do they happen? Ideally, sensors should be able to function effectively in pure real samples such as whole blood without any sample dilution or processing (Li et al., 2017). Acc. Measure the nutritional value fresheners, flavor and safety of food. Limited or confined temperature range. Electrochemical (EC) sensors are a class of sensors that use electrochemical transducers as electrodes to recognize various indistinguishable, flammable gases and a wide range of organic and inorganic contaminants. The main properties are it is 97.7% transparent and is used for making transparent conducting electrodes. Analog hardware accelerator blocks enable sensor diagnostic measurements such as electrochemical impedance spectroscopy and chronoamperometry. You may also use a computer which uses many different sensors. Seconds-resolved pharmacokinetic measurements of the chemotherapeutic irinotecan in situ in the living body. The electronic nose (e-nose) was proposed in the 1980s to tackle the selectivity. Disadvantages of electrochemical sensors include: Narrow or limited temperature range. Uric acid electrochemical sensing in biofluids based on Ni/Zn hydroxide nanocatalyst. 6, 924. In confined space applications, they are the most widely used sensors. Figure 4. doi: 10.1021/jacs.8b09397, Keywords: electrochemical sensor, nanomaterial, real samples, stability, reproducibility, limit of detection (LOD), interference, Citation: Ferrag C and Kerman K (2020) Grand Challenges in Nanomaterial-Based Electrochemical Sensors. 4, 743746. KK revised and edited the manuscript. Efforts to overcome this problem often involve the synthesis of core-shell structures and capping with stabilizing agents in order to preserve the colloid from aggregating or degrading. Throughout the experiment, the sensor was periodically pulled out from the environmental chamber and allowed to settle for an hour. They detect and Unlock the Potential of Electrochemical Sensors and Electrodes with Sentek - itechfy Active Shooter/Active Threat: Are You Prepared? The Co2Te3 electrode performs better than other CO2 detectors . The manufacturing process itself, while highly automated, inevitably introduces variability to every sensor. They are sensitive to temperature and, therefore, the sensors typically are internally temperature compensated. In cases where the temperature can shift dramatically between high and low, the sensor can produce a false alarm. Cloudflare Ray ID: 7a2c15acbec8523f True picomolar neurotransmitter sensor based on open-ended carbon nanotubes. The most widely recognized strategy for detecting the location of oxygen and harmful gases, for example, carbon monoxide and hydrogen sulfide. Angew. In this Review, the recent progress of sweat sensors has been . Disadvantages of electrochemical sensors include: Narrow or limited temperature range. (2020). 1:583822. doi: 10.3389/fsens.2020.583822. Real samples often contain many species that can easily adsorb onto the surface. The electrolyte is isolated using a membrane. Combining these highly stretchable materials with the excellent electrical conductivity of nanomaterials makes for remarkable sensors with superior analytical performance characteristics (Kim et al., 2018; Li et al., 2019; Meng et al., 2020). Locate and measure environmental pollutants. However, the equipment required for these measurements is usually expensive and bulky. Electrochemical sensors operate by reacting with the gas of interest to produce an electrical signal proportional to that gas concentration. degree in electronic engineering from Brno University of Technology, Czech Republic. Secondly, technical challenges exist throughout the systems life. Bioanal. Optical biosensors that utilize the properties of light for detection have advanced, bringing a new spectrum of real-time monitoring, faster response, improved accuracy . Electrochemical gas sensors are a proven technology that dates back to the 1950s, when they were developed for oxygen monitoring. An electrochemical sensor based on oxidized graphitic carbon nitride (Ox-g-C 3 N 4) modified electrochemical paper-based analytical device (ePAD) was fabricated for the detection of norovirus DNA. Prior to the modification, they were washed with double deionized (MilliQ) water and dried under nitrogen flow. Typically, electrochemical sensors have a limited shelf lifeusually six months to one year. For urine samples, the main challenge is the different pH ranges found which can impact the position of peak potential and the height of current intensity as well as cause stability issues (Azeredo et al., 2020). (2020). Shorter the life span due to greater exposure to the target gas. Fortunately, the breakthrough created through the applications of nanomaterials represents a significant advancement that impacts across all the fields mentioned above. Actually a two-electrode sensor (sensing and counter electrode), has many disadvantages. The life expectancy of a sensor is predicted by its manufacturer under normal operating conditions. Core cutting machines: What they do, and why you need one, Smart sensors Characteristics and applications, The rise of indoor positioning systems (IPS), Key sensing technologies in a smart factory, Types of exteroceptive sensors for mobile robots, Types of proprioceptive sensors for mobile robots. Soc. The liquid phase exfoliation method of 2D Co2Te3 production is used to achieve the electrochemical sensing of CO2. Luckily, they are a relatively inexpensive piece of equipment to replace. Just like in any other electronics system, integration is a logical step in evolution, enabling the design of more efficient and more powerful solutions. The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. With the ability to scan large areas such as factory floor as well as in confined spaces, electrochemical sensors have become integral parts of an organizations leak detection arsenal. doi: 10.1021/acs.jpcb.7b11504, Quesada-Gonzlez, D., and Merkoi, A. doi: 10.1002/anie.200600033, de Castro, L. F., de Freitas, S. V., Duarte, L. C., de Souza, A. C. J., Paixo, T. R., and Tomazelli Coltro, W. K. (2019). Disadvantages of electrochemical sensors include: Narrow or limited temperature range. A simplified block diagram of a single measurement channel is shown in Figure 1. This review (with 307 refs.) Lighting up biosensors: now and the decade to come. Their sensors have the ability to detect harmful gasses in the range of parts per million. B. One of the first applications of this technology was a glucose biosensor, where it was used to measure the depletion of oxygen in glucose. When the gas comes into contact with the sensor, it first passes through a small capillary-like opening, then diffuses through a hydrophobic barrier before reaching the electrode surface. The most common issues faced by biosensors are the detection of desired low concentration analyte in presence of interfering substances in the sample, reusability with reproducible results and. Figure 3. 47, 46974709. The need to detect, measure, and then notify people of a potential danger is critical. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and . doi: 10.1016/j.talanta.2018.10.040, PubMed Abstract | CrossRef Full Text | Google Scholar, Azeredo, N. F. B., Gonalves, J. M., Rossini, P. O., Araki, K., Wang, J., and Angnes, L. (2020). Today, it remains the most popular sensing method for detecting oxygen and toxic gases such as carbon monoxide and hydrogen sulfide. Cross-sensitivity of other gases. GAO pushes FAA for a stronger drone safety strategy, CPWR: 65% of construction deaths linked to Focus Four hazards, CA appeals board clarifies outdoor worksite drinking water requirement, Workers comp study looks at long COVID claims, Unpredictable schedules adversely affect worker well-being: report, Safety is King: NYC videos focus on fall protection, Deadline to submit OSHA Form 300A data is March 2, Study links physically demanding jobs to higher male fertility, Construction safety: Prevent falls through skylights and other openings, FACE Report: Machine operator fatally struck by safety block ejected from mechanical power press, FACE Report: Site superintendent run over by backing dump truck, Selecting safe vehicles for your employees, Eye protection options for prescription lenses, Creating an ergonomic safety knife program, The aging workforces effect on electrical safety, Big Ambitions. Chronoamperometry (pulse test) is another technique that can aid with sensor health analysis. Some sources say that because the sensor cap of an optical sensor is more . The subject of electrochemical sensors is broad, spanning many aspects of physical and analytical chemistry, materials science, biochemistry, solid-state physics, device fabrication, electrical engineering, and even statistical analysis. Cross-affectability of different gases. Therefore, application specific analog front ends with diagnostic capabilities are employed to reduce the impact of disadvantages of the technology, mainly the limited sensor life, to ensure long-term sustainability and reliability of the gas sensing systems. To overcome this challenge, nanomaterials have been incorporated within the electrode surfaces (Quesada-Gonzlez and Merkoi, 2018; Muniandy et al., 2019). Soft and flexible material-based affinity sensors. Different types of corrosion testing offer their own set of advantages and disadvantages, and selecting the right method should be based on the application and material being tested. The pulse amplitude is generally very low (for example, 1 mV) and short (for example, 200 ms), so that the sensor itself is not disturbed. 4. Compared to other diagnostic tools currently available, electrochemical sensors have many advantages such as low-cost, rapid and real-time detection with simple operation (Idili et al., 2019; Ligler and Gooding, 2019). Non-invasive, transdermal, path-selective and specific glucose monitoring via a graphene-based platform. (2019). (2019). Understanding the market trends and needs of the customers helped Analog Devices design a highly integrated, on-chip measurement system that includes: The ADuCM355 provides the means to overcome the technical challenges of electrochemical gas sensing. Strict regulations are in place to ensure that gas sensing systems meet these requirements and maintain reliable, full functionality when operating in harsh industrial environments such as chemical factories. Electrochemical machining is a high-cost installation. This value entails the lowest concentration or quantity of a specific analyte that can be reliably detected within an acceptable signal-to-noise ratio. No use, distribution or reproduction is permitted which does not comply with these terms. Bioelectron. 5. 39:107398. doi: 10.1016/j.biotechadv.2019.05.004, Muniandy, S., The, S. J., Thong, K. L., Thiha, A., Dinshaw, I. J., and Lai, C. W.. (2019). Electrochemical sensors have demonstrated a great potential for the future of diagnostic tools. doi: 10.1016/j.bios.2019.04.058, Sljukic, B., Banks, C. E., and Compton, R. G. (2006). This allows the test to be performed quite frequently, while maintaining normal operation of the gas sensing instrument. They can also be mass-produced and miniaturized into portable devices (Li et al., 2017; Idili et al., 2019; Ligler and Gooding, 2019). An electric current proportional to the gas concentration flow between the anode and the cathode when a resistor is connected across the electrodes. Biosens. Temperature is a big factor for electrochemical sensors, and they typically are internally temperature compensated. Chem. Tear fluid is often used to investigate the progression of ocular diseases and diabetes (Tseng et al., 2018; Sempionatto et al., 2019). The gas reacts at the sensing electrodes surface via an oxidation or reduction mechanism. A. In cases where the temperature can shift dramatically between high and low, the sensor can produce a false alarm. The sensor electrodes act like antennas that can pick up interference from nearby electronic systems. This may take some time to load. Electrochemical sensors have an enormous potential in a wide variety of environmental, industrial, and medicinal applications. The electrode materials developed specifically for the gas of interest catalyze these reactions. When using these sensors, the soil becomes part of an electromagnetic circuit, and changing local conditions immediately affect the signal recorded by a data logger. If this happens, it may interfere with the ions' ability to carry current. Rev. J. Phys. It is a type of resistive displacement sensor. A., Vokhmyanina, D. V., Karyakina, E. E., and Kayrakin, A. As you can imagine this poses a serious problem in any work environment. Limited Visibility. 6, 15561558. Salivary diagnostics on paper microfluidic devices and their use as wearable sensors for glucose monitoring. Applications The applications of the buzzer include the following. Depending on the target gas and the environment, an electrochemical sensor has a shelf life of six months to one year. doi: 10.1021/nl060366v, Suherman, A. L., Ngamchuea, K., Tanner, E. E. L., Sokolov, S. V., Holter, J., Young, Y. P., et al. 49, 54465472. The data is then presented as, most commonly, Nyquist plots and Bode plots. Substance specific electrochemical sensors are designed to only detect and measure particular gases. Michal Raninec The other one is the Nyquist Plot. This means if there is one part harmful gas to 999,999 parts normal oxygen, the sensor will be able to detect and alarm you of this danger. The advancement of sensors could truly help stop the spread of many infectious diseases (Vermisoglou et al., 2020) and detect the early onset of various illnesses such as neurodegenerative diseases (Kim et al., 2020). These sensors might be very reliable and accurate but more often than not they need to be replaced on a regular basis. If you are an author contributing to an RSC publication, you do not need to request permission Chem. Click on 'Write for us' to contact us. The usual practice in this case is to bring the instrument offline and inspect the sensor manually, which is both time consuming and expensive. Wearable bioelectronics: enzyme-based body-worn electronic devices. As galvanic DO sensor is self-polarizing, the anode is continuously consumed even when the sensor is not in use. CF wrote the original draft of the manuscript. It also depends on the brand and the environment in which it is used. The poor gas selectivity problem has been a long-standing issue for miniaturized chemical-resistor gas sensors. Electrochemical Sensing of Perfluorooctanesulfonate (PFOS) Using Ambient Oxygen in River Water Rebecca B. Clark and Jeffrey E. Dick ACS Sensors 2020 5 (11), 3591-3598 The synthesized Ox-g-C 3 N 4 nanosheets were characterized by field emission scanning electron microscopy (FESEM), X-ray Diffraction (XRD), UV-Vis . Acta 187, 111. Non-specific adsorption reduction methods in biosensing. The correlation between sensor sensitivity (left graph) and impedance (right graph) during accelerated lifetime test in low relative humidity. Michal received his M.Eng. They have opened a new era in which heavy equipment is no longer required to identify any disease. Chem. They play an increasing role in air monitoring and numerous workplace and hazardous leak detection applications during assembling, ecological and clinical observation. To request permission to reproduce material from this article, please go to the Short or limited shelf life. Detect glucose, acetic acid, glutamic acid, ethanol and biochemical oxygen demand (BOD) in a sample. (2018). Biosens. Copyright 2020 Ferrag and Kerman. (Anonymous comments are welcome; merely skip the name field in the comment box. and diagrams provided correct acknowledgement is given. The major shortcoming of this data representation is losing the frequency information. The complexity of traditional signal chains, which are in most cases designed with standalone analog-to-digital converters, amplifiers, and other building blocks, forces designers to compromise on power efficiency, measurement precision, or PCB area consumed by the signal chain. Chem. When using nanomaterials, long-term stability might become a major concern due to issues related to aggregation and flaking of nanomaterial-modified layers. (2018). However, the technology has also disadvantages. To continue advancing in the right direction, it is important for researchers to keep on developing innovative solutions in order to introduce more smart sensors in our everyday life. Typical electrochemical gas sensor signal chain (simplified). The detector design with the electronics can be simple and compact, allowing the construction of portable instruments, especially when conductometric, potentiometric, and amperometric detection is used. 27. Read more about our privacy policy. The robustness of electrochemical methods allows for accurate detection even in heterogeneous and impure samples. Chem. Even in the absence of analyte, a small, measurable current flows through an electrochemical cell. Advances in nanotechnology have led to the development of ultra-sensitive and high-performance platforms, including colorimetric, fluorometric, chemiluminescent, surface-enhanced Raman scattering, and electrochemical biosensors 9. Two measurement channels support not only the most common 3-electrode gas sensors, but also the 4-electrode sensor configuration. What sensors do burglar alarms use? addresses the recent advances in electrochemical nonenzymatic ascorbic acid (AA) sensors using various nanomaterials as sensing elements. Sensor manufacturers often specify that the sensor sensitivity can drift by up to 20% per year. Take a quiz about this issue of the magazine and earn recertification points from the Board of Certified Safety Professionals. 35272), Discovery Grant (Project no. Electrochem. Disadvantages of Electrochemical machining: It is time-consuming since the process needs to be done multiple times to achieve desired results. Chem. Flexible sweat sensors have found widespread potential applications for long-term wear and tracking and real-time monitoring of human health. Different types of sensors exist and the most commonly available hydrogen sensors include Electrochemical, MEMS, Chemochromic sensors. In addition, as mentioned previously, nanoparticles tend to alter their behavior under varying environmental conditions. The Nyquist plot shows the complex impedance data, where each frequency point is plotted by the real part on the x-axis and imaginary part on the y-axis. doi: 10.1007/s00604-020-04351-2, Baghelani, M., Abbasi, Z., Daneshmand, M., and Light, P. E. (2020). It is important that the application information be reviewed before deciding on the technology best suited to your application. Pros and cons of nine popular battery technologies, Benefits and limitations of robo-advisors in wealth management, 9 best ways to automate your investing strategies, Common threats and attacks against video surveillance cameras. The oxygen sensors are also used to measure oxygen level in exhaust gases emanating due to combustion of fuel or coal inside furnace, boiler or steam generator. Sci. If porous nanostructures are used as gas sensing . Notably, the stability of sensors has also been a challenge limiting their applications in remote locations under varying temperature conditions. The construction of an EC gas sensor itself has a negative impact on EMC performance. For example, the current circumstances of the COVID-19 pandemic demonstrated the importance and urgency of having accurate and rapid diagnostic devices (Jiang et al., 2020). Unfortunately, the unmodified surfaces often lack the sensitivity and selectivity required for the electrochemical detection of trace analytes. If you want to reproduce the whole article All these advantages give the sensor a better selectivity and sensitivity toward the detection of specific analytes as well as a superior overall performance (Quesada-Gonzlez and Merkoi, 2018; Ligler and Gooding, 2019; Muniandy et al., 2019; Jiang et al., 2020; Kim et al., 2020; Vermisoglou et al., 2020). However, the more the sample is diluted, the further it is from reality. This method allows just enough gas to react at the sensing electrode to generate a sufficient electrical signal while keeping the electrolyte from leaking out of the sensor. Both time and cost expenses could potentially be reduced by using integrated signal chain solutions that have been pretested to meet EMC requirements. You have entered an incorrect email address! Save lives, from the workplace to anyplace. If you are the author of this article, you do not need to request permission to reproduce figures Brief descriptions of the sensors are given along with their advantages and disadvantages. We use cookies to provide you with a better experience. The greater the exposure to the target gas, the shorter the life span. Over time the sensor drifts away from its calibration which induces prob-lems in longer fermentations. A voltage is applied between the two electrodes. Click to see full answer What are the disadvantages of pressure sensors? Disadvantages The disadvantages of the buzzer include the following. Electrochemical sensors can be built specifically for a particular gas or vapor in the parts-per-million range. Looking back at the example of a multigas instrument, thanks to the signal chain integration it is possible to: While the signal chain integration is a significant step forward, on its own it does not address the fundamental disadvantage of electrochemical gas sensorsdeteriorating performance over their lifetime. Electrochemical detection of specific biological molecules is a powerful means for detecting disease-related markers. Economical operation of these sensors enabled deployment of area toxic gas monitoring systems, ensuring safe environmental conditions for employees in industries such as mining, chemical industries, biogas plants, food production, pharmaceutical industries, and many others. Electrochemical sensors used to detect various gases may appear similar, but their functions are vastly different. Due to these variances, the sensors must be characterized and calibrated in production. * (2020). In the past few decades, numerous techniques, including electrochemical sensors, fluorescence, calorimetry, and gas chromatography, have been applied to recognize glucose concentration in foodstuff products and . Extreme temperatures and low humidity can dry out the electrodes in the device thereby shortening its lifespan. On the other hand, the disadvantages of these techniques, such as the long detection period and costly tools, should not be ignored . (2017). 139, 1120711213. Cross-sensitivity of other gases. Electrochemical detection in flow analysis has several advantages and disadvantages. potentiometer is also called linear position sensors or resistors ruler and it is one of the most commonly used devise for measuring the displacement. Electrochemical sensors are sensitive to interfering gases thereby causing the gauge to issue a false alarm. Non-invasive continous glucose monitoring system using a chipless printable sensor based on split ring microwave resonators. 49, 510533. Comments that contain personal attacks, profanity or abusive language or those aggressively promoting products or services will be removed. In this review, we identify four label-free electrochemical biosensing mechanisms: (a) blocking the electrode surface, (b) allowing greater access to the electrode surface, (c) changing the intercalation or . Both passive and active methods have been used. . A major limitation is their unsuitability for trace oxygen measurements when reducing gases (hydrocarbons of any species, hydrogen, and carbon monoxide) are present in the sample gas. Acc. It has a vulnerable membrane that is easily broken, which stops the oxygen regulation. Disadvantages of electrochemical sensors include: Narrow or limited temperature range. Disadvantages of colorimetric sensors: Limited sensitivity: Colorimetric sensors may have limited sensitivity compared to other sensing techniques such as electrochemical sensors or mass spectrometry. This swing may require the sensors calibration settings to be reset. Types of Sensors, Advantages & Disadvantages of all types Sensors, Applications of Sensors One type of feedback frequently needed by industrial-control systems is the position of one or more components of the operation being controlled. Chem. Non-specific adsorption has been one of the main roadblocks against utilizing electrochemical sensors in real-life applications because it tends to significantly decrease sensitivity, specificity, and reproducibility of the sensors. Electrochemiluminescence based enzymatic urea sensor using nanohybrid of isoluminol-gold nanoparticle-graphene oxide nanoribbons. 28. Chem. doi: 10.1021/jacs.7b05412, Li, T., Li, Y., and Zhang, T. (2019). On the other hand, humidity higher than 60% leads to water from the air being absorbed into the sensor, diluting the electrolyte and influencing sensors characteristics. Biosens. The most common misunderstanding about electrochemical sensors is that they all work in the same way. Advantages of electrochemical sensors include: Disadvantages of electrochemical sensors include: Electrochemical sensors are a proven technology that have been used for many years, and will continue to be the cornerstone of gas detection sensors. Fetching data from CrossRef. By continuing to browse the site you are agreeing to our use of cookies in accordance with our. *Correspondence: Kagan Kerman, kagan.kerman@utoronto.ca, https://doi.org/10.3389/fsens.2020.583822, Creative Commons Attribution License (CC BY). 137, 161170. Metallic nanoparticles and quantum dots possess remarkable conductive and optical properties that give a higher sensitivity to electrochemical sensors (Ismail et al., 2017; Ponnaiah et al., 2018; Ligler and Gooding, 2019). Chem. Anal. Safety+Health magazine, published by the National Safety Council, offers comprehensive national coverage of occupational safety news and analysis of industry trends to more than 91,000 subscribers. Recently, some of the most reported nanomaterials used in the fabrication of electrochemical sensors have been different forms of graphene, such as graphene nanoribbons (Ismail et al., 2017) and graphene flowers, which allow for good conductivity and fast electron transfer rates (Ismail et al., 2017; Quesada-Gonzlez and Merkoi, 2018; Muniandy et al., 2019; Jiang et al., 2020; Vermisoglou et al., 2020). Doesnt get harmed by other gases. The innovation for electrochemical detecting began in the mid-1950s. 92, 85368545. Its high carrier mobility (200,000 cm 2 v 1 s 1 . Despite the increasing variety of advanced tools to identify hazardous chemicals and gas, still one of the most widely used sensors are the electrochemical ones. doi: 10.1002/elan.201600477, Jiang, Z., Feng, B., Xu, J., Qing, T., Zhang, P., and Qing, Z. electrochemical sensors in agriculture is in the direct measurement of soil chemistry through tests such as pH or nutrient content. Additionally, these sensors can self-calibrate enabling them to be extremely accurate and reliable even under harsh working conditions. The ideal operating conditions for an electrochemical gas sensor are 20C and 60% relative humidity. What are the advantages and disadvantages of electrochemical sensors? Due to the innovation of nanomaterial-modified surfaces, LODs with values as low as picomole and femtomole levels have been achieved in the case of some ultra-sensitive sensors (Suherman et al., 2017; Li X. et al., 2018; Ponnaiah et al., 2018; Alizadeh et al., 2019; Wu et al., 2019; Gupta et al., 2020). However, the challenges outlined above, not only apply for clinical applications, but also across other fields such as environmental monitoring, food safety, forensic analysis, agriculture, defense, and military applications as well as electronics industry. Materials, structures, and functions for flexible and stretchable biomimetic sensors. To help overcome the matrix effect, researchers frequently dilute the samples in order to shift the effect of interferences below a tolerable threshold. They are an extremely cost-effective piece of equipment to use. Miao et al.7recently reviewed electrocatalysis and This means they can be connected to laptops, tablets or smartphones. Subscribe today! Please enable JavaScript in the characterization of liquid properties, namely density and viscosity, in electrochemical studies and . Big Ambitions. when compared to other methods, EMC offers poor surface finish and uniformity because of its nature of using solvents instead of metals.
Connect Switch Lite To Mac,
Texas Commercial Vehicle Registration Renewal,
Non Consequentialist Theory Weaknesses,
Articles D